Table 3- 53
Meaning of the LEDs on the Terminal Module TM54F
LED
Color
READY
-
Green
Orange
Red
Green/red
Green/orange
or
Red/orange
L1+, L2+,
Red
L3+
Red
202
Status
Off
Electronics power supply is missing or outside permissible
tolerance range.
Continuou
The component is ready for operation and cyclic DRIVE-
s light
CLiQ communication is taking place.
Continuou
DRIVE-CLiQ communication is being established.
s light
Continuou
At least one fault is present in this component.
s light
Note:
The LED is activated irrespective of whether the
corresponding messages have been reconfigured.
Flashing
Firmware is being downloaded.
light 0.5
Hz
Flashing
Firmware download is complete. Wait for POWER ON
light 2 Hz
Flashing
Component recognition via LED is activated (p0154).
light
Note:
Both options depend on the LED status when component
recognition is activated via p0154 = 1.
ON
The controllable sensor power supply is functioning fault-
free.
Continuou
There is a fault in the controllable sensor power supply.
s light
ON
Sensor power supply is functioning fault-free.
Continuou
There is a fault in the sensor power supply.
s light
Description, cause
Commissioning Manual, (IH1), 01/2011, 6SL3097-4AF00-0BP1
Remedy
Remedy and
acknowledge
fault
Carry out a
POWER ON