Diagnostics
3.2 Diagnostics via STARTER
Parameterizing and operating the ramp-function generator
The function generator is parameterized and operated via the STARTER commissioning
tool.
Figure 3-1
"Ramp-function generator" initial screen
Note
Please refer to the online help for more information about parameterizing and operation.
Properties
● Concurrent injection to several drives possible.
● The following parameterizable signal shapes can be set:
● An offset is possible for each signal. The ramp-up to the offset is parameterizable. Signal
● Restriction of the output signal to the minimum and maximum value settable.
206
– Square-wave
– Staircase
– Triangular
– Sinusoidal
– PRBS (pseudo random binary signal, white noise)
generation begins after the ramp-up to the offset.
Commissioning Manual, (IH1), 01/2011, 6SL3097-4AF00-0BP1
Commissioning Manual