Diagnostics
3.1 Diagnostics via LEDs
3.1.3.4

Sensor Module Cabinet SMC10 / SMC20

Table 3- 42
Sensor Module Cabinet 10 / 20 (SMC10 / SMC20) – description of the LEDs
LED
Color
RDY
-
off
READY
Green
Continuous
Orange
Continuous
Red
Continuous
Green/
0.5 Hz
red
flashing
light
2 Hz
flashing
light
Green/
Flashing
orange
light
or
Red/
orange
192
Status
Electronics power supply is missing or outside permissible
tolerance range.
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
DRIVE-CLiQ communication is being established.
At least one fault is present in this component.
Note:
LED is driven irrespective of the corresponding messages
being reconfigured.
Firmware is being downloaded.
Firmware download is complete. Wait for POWER ON
Component recognition via LED is activated (p0144)
Note:
Both options depend on the LED status when component
recognition is activated via p0144 = 1.
Description, cause
Commissioning Manual, (IH1), 01/2011, 6SL3097-4AF00-0BP1
Remedy
Remedy and
acknowledge fault
Carry out a POWER
ON