Activating The Commissioning Mode - Siemens SINUMERIK Series Function Manual

Safety integrated
Hide thumbs Also See for SINUMERIK Series:
Table of Contents

Advertisement

3.2

Activating the commissioning mode

You can call the commissioning mode both for the safety settings as well as for the individual
safety functions.
Procedure
Safety Integrated
Function Manual, 10/2015, 6FC5397-3EP40-5BA3
1.
Select the "Start-up" operating area.
2.
Press the menu forward key and the "Safety" softkey.
3.
Press the "Settings" softkey, and then select a setting area (e.g. options)
using the appropriate softkeys.
- OR -
Press the "Functions" softkey, and then select a safety function (e.g.
SBC) using the appropriate softkeys.
4.
Select the required drive using softkey "Drive+", or "Drive-".
- OR -
Press the "Select drive" softkey.
This softkey is only visible if there are several drives.
A selection of all of the axes and drives that exist in the drive system is
displayed.
Select the required drive.
Press the "OK" softkey to complete the drive selection.
Activating the commissioning mode for a drive
5.
Press the ">>" softkey.
Then press the "Act./deact. drv. comm." softkey
A prompt to activate the commissioning mode is displayed.
6.
Press the "OK" softkey to activate the commissioning mode for the actual
drive.
- OR -
Press the "Cancel" softkey.
In this particular case, activating the commissioning mode is canceled.
Activating the commissioning mode for all drives
5.
Press the "Change" softkey.
Commissioning - drive-based
3.2 Activating the commissioning mode
49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828dSinamics s120

Table of Contents