3 Commissioning Process
Operation Procedure
To configure the IP address and routing information of the BTS locally, do as follows:
Step 1 Log in to the BTS locally. See 3.3.2 "Locally Logging In to the BTS in Telnet Mode" for
details.
Step 2 Set the IP address of the BCIM by executing the command SET CBTSBCIMIP.
Step 3 Set the IP address of the FE port of the BCIM by executing the command ADD
CBTSFEPORT.
Step 4 Set the routing information of the BTS by executing the command ADD CBTSIPROUTE.
Step 5 Set the IP address of the BTS O&M by executing the command SET CBTSOAMIP.
----End

3.3.4 Starting the LMT

This section describes how to start the LMT.
Task Description
Log in to the BAM through the LMT.
Prerequisites
Before starting the LMT, ensure that:
Operation Procedure
To start the LMT, do as follows:
Step 1 Select Start > All Programs > iManager M2000 > LocalWS.
The Local NE Management System dialog box is displayed.
Step 2 Click Configure to add the IP address of the BAM.
Step 3 Select the BAM to be logged in to and click OK.
The system starts the service maintenance system automatically and the User Login dialog
box is displayed.
Step 4 Type in the valid user name and password, as shown in Figure 3-7.
3-12
The BTS is configured with the QC54BCIM.
The BAM server is operational.
The LMT is installed with the O&M software.
The network connection between the LMT and the BAM is normal.
The user name, password, and related authorities of the WS have been defined in the
BAM.