Reverse Rssi Test Analysis; Table 3-5 Parameters Associated With The Reverse Rssi Test - Huawei Airbridge BTS3606E Commissioning Manual

Table of Contents

Advertisement

3 Commissioning Process
Step 2 In the Windows operating system of the LMT, select Start > Run.
Step 3 In the Run dialog box, type in Telnet xxx.xxx.xxx.xxx, and then press Enter to run the
Telnet program.
Step 4 Check the BTS configuration, and ensure that the data configuration complies with the actual
cable connection of the RF subrack.
Step 5 Start reverse RSSI test.
For example, to trace the CMTR or OMTR configured in slot 1, execute the following
commands:
HW CBTS>str infotrace
<(brdtp=?bckm_omu/bckm_sig/bckm_clk/bcim/ccpm/trm), mandatory >trm
<(brdid=?),mandatory >1
<(item=?),optional>"rssi"
Ok
Step 6 Record test results.
Step 7 Stop the reverse RSSI test as follows:
HW CBTS>stp infotrace
<(brdtp=?bckm_omu/bckm_sig/bckm_clk/bcim/ccpm/trm), mandatory >trm
<(brdid=?),mandatory >1
<(item=?),optional>"rssi"
Ok
----End

3.5.4 Reverse RSSI Test Analysis

This section provides the parameters, examples, and analysis of reverse RSSI test results.
Troubleshooting methods for abnormal test results are also provided.
Parameter Description
Table 3-5 describes the parameters associated with the reverse RSSI test.

Table 3-5 Parameters associated with the reverse RSSI test

Parameter
Main Avg
Main Peak
Main Ratio
Divs Avg
Divs Peak
Divs Ratio
3-26
You can also stop the RSSI test by restarting the Telnet program.
Description
Main RSSI average value
Main RSSI peak
The main ratio is more than the main RSSI average value
Diversity RSSI average value
Diversity RSSI peak
Diversity ratio is larger than average value