Airbridge BTS3606E&3606AE
System Commissioning Guide
Procedure Description
To perform the BSS reverse maintenance, do as follows:
Step 1 Execute the command STR CBTSRVSMNT to start the reverse maintenance function.
Step 2 At the WS of the BAM side, add the WS and set the command authority for the WS of the
BCKM side by using the LMT.
Step 3 At the WS of the BCKM side, run the local NE management system or independent LMT
software to log in to the BTS.
Step 4 Use the LMT software to maintain the BSS system.
Step 5 Execute the command STP CBTSRVSMNT to stop the inverse maintenance function.
Step 6 Exit the LMT software.
----End

3.3.7 Loading the BTS Software Locally

Task Description
Load the configuration files and board software into the BTS from the WS connected with the
BCKM.
Prerequisites
Before loading the BTS software locally, ensure that:
Issue 02 (2006-10-10)
To connect the WS and the BCKM, connect a crossover Ethernet cable to the Ethernet
ports on the WS and the BCKM. The IP address of the WS and that of the BCKM Ethernet
interface must be in the same network segment.
By default, the IP address of the BCKM Ethernet interface is 172.16.16.16 and the mask is
255.255.0.0.
When adding the WS, you must set the parameter IP address to the IP address of the BTS maintenance.
For the login to the BTS, the IP address of the BAM must be the IP address (172.16.16.16) of the
BCKM Ethernet port rather than the real IP address of the BAM.
The IP address of the WS and the IP address of the BCKM are in the same network
segment.
The Ethernet port of the WS and that of the BCKM is connected by crossover Ethernet
cables.
Huawei Technologies Proprietary
3 Commissioning Process
3-15