Menu Descriptions; Menu Overview - ABB Navigator 550 Operating Instructions Manual

Hydrazine analyzer, measurement made easy
Hide thumbs Also See for Navigator 550:
Table of Contents

Advertisement

Navigator 500
Hydrazine analyzer

7 Menu descriptions

7.1 Menu overview

Refer to Section 7.1.1, page 40
Menu
Calibrate
Exit
Hydrazine 1 – 4
Sensor Calibration
Calibrate
Scheduled Calibration
Type
Frequency
Interval
Time of Next Cal.
Calibration Setup
Standard Solution
Recovery Time
Restore Defaults
Hold Outputs
Refer to Section 7.1.4, page 44
Menu
Display
Exit
Language
Settings
Operator Templates
Page 1 (5) Template
Date & Time
Chart View
Channel 1 – 4
Source
Tag
Chart Duration
View/Log Enables
Diagnostic View
Signals View
Chart View
Alarm View
Analog OP View
Calibration Log
Alarm Log
Audit Log
Refer to Section 7.1.7, page 49
Menu
Media Card
Exit
Card Status
Process Data
Channel 1 – 6
Sampling Time
Data Logging
Save Configuration
Select File Name (8)
Load Configuration
Select File (8)
Quick Format
Note. Service level menus (not shown) are
password-protected at the factory and intended for
use by authorised ABB service technicians only.
Fig. 7.1 Overview of hydrazine menus
OI/AHM550–EN Rev. A
Refer to Section 7.1.2, page 41
Select
Hydrazine 1 – 4
Refer to Section 7.1.5, page 46
Select
Analog Outputs
Analog Output 1 – 4
Brightness
Source
Contrast
Output Type
Elec. Low
Elec. High
Date Format
Eng. Low
Time & Date
Eng. High
Daylight Saving
Output Failure
DS Region
Failure Current
DS Start Time
DS End Time
DS Start Occur
DS End Occur
DS Start Day
DS End Day
DS Start Month
DS End Month
Refer to Section 7.1.8, page 50
Select
Menu
Sensor Setup
Exit
Select
Tag
Units
Range High
Range Low
Filter Type
Filter Time
Solution Detection
Flow Sensor
Man. Valve Control
High Standard Valve
Reset to Defaults
Menu
Input/Output
Exit
Select
Digital I/O
Digital I/O 1 – 6
Type
Source
Polarity
Relays
Relay 1 – 6
Source
Polarity
Menu
Communication
Exit
Select
Profibus
Slave Address
Baud rate
Ethernet
DHCP
IP Address
Subnet Mask
Default Gateway
Email
SMTP Server ID
Recipients
Email Address 1 – 3
Triggers
Tag 1 – 4
Source 1 – 4
Invert 1 – 4
Refer to Section 7.1.3, page 42
Menu
Device Setup
Exit
Select
Initial Setup
Instrument Tag
Temperature Units
Reset to Defaults
Security Setup
Calibrate Password
Advanced Password
Reset Passwords
Range Change Setup
Range Change
Range 1(3) Span
Refer to Section 7.1.6, page 48
Menu
Process Alarm
Exit
Select
Alarm 1 – 8
Source
Type
Tag
Trip
Hysteresis
Time Hysteresis
Refer to Section 7.1.9, page 51
Menu
Device Info
Exit
Select
Transmitter
Serial Number
Date of manufacture
Hardware Revision
Software Revision
Ethernet
Ethernet Revision
MAC Address
Input/Output
No. Analog Inputs
No. Analog Outputs
No. Relays
Media Card Unit
Software Version
Hardware Version
Sensor 1 – 4
Type
Serial Number
Date of manufacture
Hardware Revision
Software Revision
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Navigator 500 seriesNavigator 540

Table of Contents