Epson RC520 Safety And Installation page 32

Hide thumbs Also See for RC520:
Table of Contents

Advertisement

2. Installation
E2H, E2S, E2L
(1) Using nippers, cut off the wire tie securing Arm #2.
(2) Unscrew the cable clamp (E2H), or remove the M4 screw (E2S, E2L) on
(3) Push Arm #1 slowly in the direction shown with an arrow in the figure
NOTE
E2C
(1) Using nippers, cut off the wire tie securing Arm #2.
(2) Unscrew the M4 screw on the end of Arm #2.
(3) Push Arm #1 slowly in the direction shown with an arrow in the figure on
NOTE
The arm retaining bolt must be fastened. Otherwise, the motion range of
Joint #1 is limited.
24
the end of Arm #2.
below.
Remove the arm retaining bracket and bolt form the base.
If the bolt is not removed, the motion range of Joint #1 will be limited.
Be sure to remove the bolt.
Arm retaining bracket
Bolt
E2H : M12×20
E2S : M8×10
E2L : M12×20
the right. Fasten the arm retaining bolt on the base.
Arm retaining bolt
M8×30
The figure is E2S
RC520 Safety and Installation Rev.2