Acceptance test wizard of SINUMERIK Operate
3.2 SINUMERIK 828D/840D sl - drive-based Safety functions
8. Then evaluate the test result. Then check the list as to whether all of the expected alarms
have occurred, and whether the results in the trace recording are correct.
– To display the trace recording, press the "Display Trace" softkey.
– The "Back" softkey will take you back to the default view of the input screen.
36
The trace for this test is displayed in the input screen. You can change the display as
needed.
Figure 3-10
Example - Safety acceptance test: SOS, trace
Note
In the event of problems with the trace recording, you will find information on clearing
the problem under "Tips and tricks (Page 83)".
SINUMERIK Operate acceptance test
Function Manual, 08/2018, A5E39460574B AC