Effect Of The Acceptance Test For Specific Measures; Effects With Sinumerik 828D Safety Integrated - Siemens SINUMERIK 828D Function Manual

Sinumerik operate acceptance test
Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Actions for hardware replacement and modifications

5.2 Effect of the acceptance test for specific measures

The appropriate messages are displayed depending on the components involved (and the
control type). Example:
Warning
F01650 SI P1 (CU): Acceptance
test required
A01695 SI Motion: Sensor Module
has been replaced
C30711 SI Motion P2: Defect in a
monitoring channel
5.2
Effect of the acceptance test for specific measures
5.2.1

Effects with SINUMERIK 828D Safety Integrated

The effects of the acceptance test with certain measures are described in the following table.
Function test parts 1 and 2, as well as the supplementary measures relate to the section
Example contents of the acceptance test (Page 85).
Measure
Documentation
Replacement of
Inclusion of hard‐
the encoder sys‐
ware data
tem
Replacing an
Inclusion of hard‐
SMC, SME module
ware data/ soft‐
ware version data
Replacing a motor
Inclusion of hard‐
equipped with
ware data/ soft‐
DRIVE-CLiQ
ware version data
Replacing a Motor
Inclusion of hard‐
Module
ware data/ soft‐
ware version data
Replacing the
Inclusion of hard‐
PPU hardware
ware data/ soft‐
ware version data
Replacing the NX
Inclusion of hard‐
hardware
ware data/ soft‐
ware version data
Replacing TM54F
Possibly supple‐
hardware
ment hardware da‐
ta
76
Example
Fault value 2005
Indicates that the Control Unit has been replaced.
Indicates that the Sensor Module has been replaced.
Fault value 1031
Stop response STOP F
As a consequence of A01695, a defect is signaled in a monitoring channel.
Function test
Function test
Part 1
Part 2
No
No
No
No
No
No
Yes, only Point 2.1
No
(Page 85)
Yes
No
Yes, only Point 2.1
No
(Page 85)
No
No
Supplementary
Completion of the
measures
report
Point 4.1 (Page 85) Inclusion of
possibly new
checksums and
countersignature
Point 4.1 (Page 85) Inclusion of the
new checksums
and countersigna‐
ture
Point 4.1 (Page 85) Inclusion of the
new checksums
and countersigna‐
ture
Point 4.1 (Page 85) Countersignature
Point 4.1 (Page 85) Countersignature
Point 4.1
Countersignature
(Page 85), only for
axes controlled by
the NX
Point 4.2 (Page 85) Countersignature
SINUMERIK Operate acceptance test
Function Manual, 08/2018, A5E39460574B AC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents