Acceptance test wizard of SINUMERIK Operate
3.2 SINUMERIK 828D/840D sl - drive-based Safety functions
Figure 3-13
3. Select a directory or create a new one. Then press the "OK" softkey to confirm your
selection.
You are prompted to assign a name for the future certificate.
4. Enter the certificate name here. Then press the "OK" softkey to confirm your entry.
The certificate is then saved in the selected archive folder as RTF file. As a result of the
RTF format, the certificate can be subsequently supplemented, e.g. to include a machine
diagram.
3.2.5
Acceptance test mode
SINAMICS Safety Integrated has a parameter-supported acceptance test mode for the
following safety functions: SS2, SOS, SDI, SLS, SLP.
40
Example - Safety acceptance, save certificate
SINUMERIK Operate acceptance test
Function Manual, 08/2018, A5E39460574B AC