Panasonic ISE SMART CONNECT KNX Product Manual page 44

Table of Contents

Advertisement

2 | 102 | 202 | 302
Name
Function
Communication object no.
Possible values
Data width
Data point type/data type
Flags (CRWTUI)
Table 15: Last error
No.
Error code
11
TvComm
13
TvlpConfig
14
TxOutOfRng
15
ExecuteCmd
16
GetState
17
SrcOutOfRng
23
LnkOutOfRng
24
NoMAC
Table 16: Error codes
ISE SMART CONNECT KNX Panasonic
© 2019 ise Individuelle Software und Elektronik GmbH
Last error
Provides information on the last error.
TV 1=2
TV 2=102
TV 3=202
TV 4=302
Text that contains the number of the error code and an abbrevi-
ated error description.
14 bytes
16.001 characters
CR-T--
Description
Unable to establish communi-
cation with the TV device.
No IP address or host name is
configured.
The received value does not
exist.
Control commands are not
received.
The ISE SMART CONNECT
KNX Panasonic does not
receive an answer to the sta-
tus query.
The entered source is not
assigned.
The received value does not
exist.
The TV device MAC address
could not be determined.
Communication Objects
Possible cause / correction
• The TV device is not connected to
the network.
• The TV device is in standby mode.
Configure the IP address or host
name for the corresponding TV
device in the ETS
Check the values entered in commu-
nication object 30 | 130 | 230 | 330.
Permissible: 0 to 9.
The ISE SMART CONNECT KNX
Panasonic cannot be contacted.
The TV device is not contactable.
The value sent for source selection is
not permissible.
See table Sup-
ported sources, p. 48.
Check the values entered in commu-
nication object 32 | 132 | 232 | 332.
Permissible: 0 to 9.
The TV device was not switched on
manually for initial commissioning.
1-000C-000
S. 44 / 69

Advertisement

Table of Contents
loading