Table of Contents

Advertisement

14 | 114 | 214 | 314
Name
Function
Communication object no.
Possible values
Data width
Data point type/data type
Flags (CRWTUI)
Table 21: Previous/Next station

10.3 Sources

All supported sources have a permanently assigned number. You can control the respective source with
this number.
15 | 115 | 215 | 315
Name
Function
Communication object no.
Possible values
Data width
Data point type/data type
Flags (CRWTUI)
Table 22: Select source
ISE SMART CONNECT KNX Panasonic
© 2019 ise Individuelle Software und Elektronik GmbH
Previous/Next station
Switches the program to the previous or next program.
TV 1=14
TV 2=114
TV 3=214
TV 4=314
• 0: Reduce: switch to the previous program channel.
• 1: Increase: switch to the next program channel.
1 bit
1.007/step
C-W---
Select source
Changes the source to the defined value.
More information
see table Supported sources, p. 48.
TV 1=15
TV 2=115
TV 3=215
TV 4=315
0|...|16 or 255
Number of supported source
1 byte
5.010/meter pulse
C-W---
Communication Objects
1-000C-000
S. 47 / 69