BREAK
K1
BREAK
K2
NORMAL OPEN
ALARM
SENSOR
NORMAL
CLOSE
PIOUS
All wiring connections must be 24 AWG twisted pairs.
RELAY OPTIONS:
• K1 (DE): DOOR LOCK OR AMP MUTE CONTROL; PROGRAM 77-1, LED 07
• K2 (NH): NIGHT RELAY OR MUSIC-ON-HOLD CONTROL; PROGRAM 77-1, LED 05
• K1 & K2: 24VDC, 1 AMP MAXIMUM
FIGURE 7-7

DK16 PIOUS RELAY CONTROL FUNCTIONAL WIRING DIAGRAM

3.25 Door Lock Assignments Guide
Port
Host
No.
DK16 PIOU/PIOUS
N/A
Ckt 5 DK16
04
Base Unit DDCB
Ckt 3 DK8 KSU DDCB
02
Ckt 1 Expansion Unit
12
(PDKU or KCDU)
Ckt 4 DK8 KSU DDCB
03
Note: CKT1 must be used in installing DDCB on KCDU
or PDKU. (Must be in Port 12)
TBI
DET
W1
MAKE
DER
NHT
W2
MAKE
NHR
ALMT
W3
ALM
ALMR
Door
Prog. 39
Lock No.
Assignments
0
Code 71
Unlock
Door 0
1
Code 72
Unlock
Door 1
2
Code 73
Unlock
Door 2
MDF
DE
NH
NIGHT BELL
3.30 DK16 Expansion Unit Night Transfer/
Music-on-Hold Relay Options with PIOU or
PIOUS
3.31 The NHT/NHR relay may be programmed for
either the night relay or the MOH relay function
(refer to Figures 7-6 and 7-7). These functions can
be provided in addition to the relay service provided
by the Base Unit.
3.32 When configured for the night transfer func-
tion with Program 77-1, the relay activates if the
system is in the NIGHT mode. The relay may be
7-9
INSTALLATION-PERIPHERALS
SECTION 100-816-207
MARCH 1993
DOOR
LOCK
CONTROL
MOH
SOURCE
UNIT
FACILITY
ALARM
UNIT