FAULT FINDING
SECTION 100-816-500
MARCH 1993
2-4
Reprogram customer
data base, one program
at a time, and check
to see if fault re-occurs.
2-7
Does the fault
re-occur after
entering customer
data base?
NO
END
CHART NO. 2
CATASTROPHIC FAULTS
START
Is the system
NO
Go to
completely
Chart 1
non-operational?
YES
2-1
Check system
hardware per
paragraph 6.01 for DK8
or 7.01 for DK16
of this section.
2-2
Was the fault
isolated by completing
the system hardware
check?
NO
2-5
Re-initialize the system
(Programs 90, 92, and
03) and re-check fault
using default program
data (do not enter
customer data base).
2-6
Was the
YES
fault cleared
after re-initializing
the system?
NO
YES
2-8
Call your
technical support
group.
-8-
YES
Tag the defective
2-3
unit(s) and return
for repair.
NOTE:
Program 03 is not used for DK8.
END