Pstu Installation Procedure; Pstu And Subunit (Sstu) - Toshiba Strata DK 16 Installation And Maintenance Manual

Toshiba digital key telephone systems installation and maintenance manual
Hide thumbs Also See for Strata DK 16:
Table of Contents

Advertisement

50-PIN AMPHENOL CONNECTOR (FEMALE)
SSTU
SUBUNIT
BACKPLANE CONNECTOR
FIGURE 5-15

PSTU AND SUBUNIT (SSTU)

CONTROL/INDICATOR/
CONNECTOR
(Figure 5-15)
Ring Voltage W1 Jumper
Plug (PSTU1 (
) and
V.4
PSTU2 only)
NOTE:
PSTU1 (V.4) became available in November
1989. PSTU1(V.3) was discontinued.
9.12 Set the PSTU1 (V.4) or PSTU2 ring generator
level as required:
W1 set to H (190V P-P).
W1 set to L (130V P-P).
Two ringers maximum per port (H or L).
TABLE 5-C
PSTU CONTROLS AND INTERFACE CONNECTORS
TYPE OF COMPONENT
Three-terminal jumper
5-21
INSTALLATION-DK 16 KSU & PCB
W1
H
L
DESCRIPTION
Sets ring generator voltage level for all
circuits.
H = 190V P-P
L = 130V P-P
9.13 Unlike the PEKU or PESU, the PSTU does not
have to be configured for BGM: There is no jumper
wire to cut, etc.

9.20 PSTU Installation Procedure

9.21 Install the PSTU in accordance with the fol-
lowing steps:
1) Remove the PCB from its protective packag-
ing. The protective shield on the back of the
PSTU is designed to protect the installer from
SECTION 100-816-205
MARCH 1993
W1 Ring Voltage
H = 190V P-P
L = 130V P-P
(For PSTU1 (V.4)
and PSTU2 only)