E93: Software Configuration error

E93
Wrong MCF data loaded
Checks to perform:
Replace the Electronic Control Board and repeat the Diagnostic Cycle to check for any further alarms.

E94: Software Configuration error

E94
Microprocessor corrupted
Checks to perform:
Replace the Electronic Control Board and repeat the Diagnostic Cycle to check for any further alarms.

E97: Software Configuration

E97
Wrong MCF data loaded cycle selector switch failure.
Checks to perform:
Replace Cycle Selector Switch and retry if the problem still exists, replace the Electronic Control Board and repeat the
Diagnostic Cycle to check for any further alarms.