E93: Software Configuration error
E93
Wrong MCF data loaded
Checks to perform:
Replace the Electronic Control Board and repeat the Diagnostic Cycle to check for any further alarms.
E94: Software Configuration error
E94
Microprocessor corrupted
Checks to perform:
Replace the Electronic Control Board and repeat the Diagnostic Cycle to check for any further alarms.
E97: Software Configuration
E97
Wrong MCF data loaded cycle selector switch failure.
Checks to perform:
Replace Cycle Selector Switch and retry if the problem still exists, replace the Electronic Control Board and repeat the
Diagnostic Cycle to check for any further alarms.
135
WARNING
Check that all the connectors are correctly inserted
WARNING
Check that all the connectors are correctly inserted
WARNING
Check that all the connectors are correctly inserted
E93
E94
E97