E55: Motor Under-speed failure

E55
Foam or drum weight overload, Drum mechanical drag, Motor, Drain pump.
Checks to perform:
Is the power supply as per product specification? (Voltage =
240V (Electric), 120V (Gas) Models and Frequency = 60HZ)
Is the laundry load as per product specification? (Load
Capacity = 10.1 Kg (Approx.))
Remove the laundry and check whether the drum turns
freely without posing any resistance. Is the drum having any
difficulty in rotating? (See Fig .1)
Is the resistance measurement of the Motor approximately
6Ω to 8Ω ? (Measure it directly on the Motor terminals 1 &
2, 2 & 3, and 1 & 3 without wiring) (See Fig. 2)
Is the resistance measurement of Motor approximately 6Ω
to 8Ω? (Measure it directly on the Motor wiring connector
on the Motor Control Board side between terminals J2-1 &
J2-2, J2-2 & J2-3 and J2-3 & J2-1)(See Fig. 3)
See Next Page
Y
E
S
Y
E
S
N
O
Y
E
S
Y
E
S
WARNING
Check that all the connectors are correctly inserted.
Make the power supply proper as per product
NO
specification and repeat the Diagnostic Cycle to check
Make laundry load as per product specification and
NO
repeat the Diagnostic Cycle to check for any further
Replace / Repair the defective component and repeat
YES
the Diagnostic Cycle to check for any further alarms.
Replace the Motor and repeat the Diagnostic Cycle to
NO
check for any further alarms.
Replace / Repair the wiring and repeat the Diagnostic
NO
Cycle to check for any further alarms.
175
for any further alarms.
alarms.
E55