Frigidaire FFLE3911QW Technical & Service Manual page 158

Table of Contents

Advertisement

15.14 Alarms Summary Table
Alarm
S. NO.
Alarm Code
Description
33
EBE
Motor Control
Board Relay
(EHE)
error
34
EBF
Motor Control
Board relay
(EHF)
sensing error
35
EC6
Clutch Alarm
36
EC7
Clutch triac
sensing Failure
37
EF2
Foam warning
38
EF6
Safety reset
Fault
Possible Fault
Condition
Incongruence
Motor Control Board Relay
between
defective
safeties relay
Wiring or main board
sensing and
defective
Motor Control
Board relay
status
Input voltage
Main board
value on
microprocessor
always to 0V or
to 5V
Clutch
Clutch mechanism failure
positioning
Main board defective
timeout to
Wiring/connection problem
reach or failure
to stay in
desired position.
The sensing of
Clutch mechanism failure
the clutch triac
Main board defective
is out of the
Wiring/connection problem
limits.
Suds lock
Incorrect or excessive
detected during
detergent
spin phase at
Drain pipe blocked or
the end of the
clogged
washing phase
Main Board
Main Board defective
microcontroller
damaged
157
Action
Machine Action/
to
Status
Clear
Safety drain
RESET
Cycle abort
Safety drain
RESET
Cycle abort
Cycle abort
-
Cycle abort
-
Alarm is silent
-
and the cycle is
extended
None
-
Page
No
191
191
192
193
194
194

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fflg3911qwFfle4033qwFflg4033qw

Table of Contents