Reconnect the connector and measure approximately
1375Ω ± 10% on the Solenoid Valve wiring connector on
Replace / Repair the wiring and repeat the Diagnostic
the circuit board side between terminals J20-1 & J20-3,
NO
Cycle to check for any further alarms.
J18-1& J18-3 and J18-4 & J18-6 (See Fig. 5). Is the
Solenoid Valve wiring ok?
Y
E
S
Replace the Main Control Board and repeat the Diagnostic Cycle to check for any further alarms.