14.9 Pressure Sensor Accessibility

NOTE
1. Remove the dryer unit to access the Solenoid Valve and Pressure sensor.
2. Remove a total of 7 screws and two service professionals are required to remove in the dryer unit.
Step: 1
Below figure shows top view of washer unit after dryer unit is removed.
Step: 2
Detach the Pressure Sensor snap that fits with the Rear Panel of the washer unit (Figs. 1a and1b) and detach the connector
(Fig.2), then remove the pressure tube at the switch end (See Fig. 3).