15.14 Alarms Summary Table
Alarm
S. NO.
Alarm Code
Description
25
E93
Machine
configuration
error
26
E94
Cycle
Configuration
error
27
E97
Software
selector
and cycles
configuration
error
28
E98
Motor control
to main board
software error
29
E9C
User interface
configuration
fault
30
EB1
Power supply
frequency out
(EH1)
of limits
31
EB2
Power supply
voltage too high
(EH2)
32
EB3
Power supply
voltage too low
(EH3)
Fault
Possible Fault
Condition
Incorrect
Main board
configuration of
appliance
Incorrect
Main Board
configuration of
washing cycles
Incongruence
Main Board
between
program
selector
and cycle
configuration
Protocol
Main board
communication
Motor Control Board
between Motor
Control Board
and MB not
aligned
Configuration
User interface
wrongly or not
received
Power supply
AC input
period lower/
Main Board
higher than
configured
values
MAIN_V sensing
High AC input voltage
input voltage
Main Board
value greater
than configured
value
MAIN_V sensing
Low AC input voltage
input voltage
Main Board
value lower than
configured value
156
Action
Machine Action/
to
Status
Clear
Cycle blocked
OFF/ON 187
Cycle blocked
OFF/ON 188
Cycle blocked
RESET
Cycle blocked
OFF/ON 189
No actions
ON/OFF
START
RESET
Wait for improved
OFF/ON 190
power supply
conditions
Wait for improved
OFF/ON 190
power supply
conditions
Wait for improved
OFF/ON 191
power supply
conditions