EC6: Clutch alarm

EC6
Clutch mechanism failure, Main board defective, Wiring/connection problem.
Checks to perform :
Is Clutch assembled properly? (Check for any damage) Is
Clutch in good condition?
Is the resistance measurement of the clutch approximately
2800Ω to 3100Ω ? (Measure it directly on the clutch
terminals without wiring). (See Fig. 1)
Is the resistance measurement of clutch approximately
2800Ω to 3100Ω ? (Measure it directly on Clutch wiring
connector on the Main Control Board side between
terminals J9-1 & J20-6) (See Fig. 2)
Replace the Main Control Board and repeat the Diagnostic
Cycle to check for any further alarms.
Y
E
S
Y
E
S
Y
E
S
WARNING
Check that all the connectors are correctly inserted.
Replace / Repair the Clutch and repeat the Diagnostic
NO
Cycle to check for any further alarms.
Replace the Clutch and repeat the Diagnostic Cycle to
NO
check for any further alarms
Replace / Repair the wiring and repeat the Diagnostic
NO
Cycle to check for any further alarms.
Replace / Repair the wiring and repeat the Diagnostic
NO
Cycle to check for any further alarms.