S.NO
Component
1
Pressure Sensor
Presssure Frequency Diagram
Pressure (mm H2O)
Water Level at 0*
Mm H20* - Hz* : Points with 100% control of frequency output on assembly line
( At Water Level "0" mm (empty tub) Frequency will be 45.4 Hz )
150*
200*
350*
500*
600
Specifications
Nominal Voltage : 5 ± 0.25 VdC; maximum current: <5 mA;
Maximum Operating Temperature: 85 ºC (65 ºC for UL application);
Pressure working range 0 - 600 mm of H2O.
95
Nominal frequency (Hz)
45.400*
43.140*
42.350*
39.990*
37.772*
36.560