20. Faulty second feed motor (related to MS3)
Cause
Safety range switch
(MS3)
Shutter closed detection
switch (MS4)
Finisher controller PCB
Step
Checks
1
Check the safety range switch.
Is the switch normal?
2
Is the safety range detection
switch passed correctly?
3
Check the shutter closed
detection switch. Is the switch
normal?
4
Is the shutter closed detection
switch pressed correctly?
CHAPTER 7 TROUBLESHOOTING
Yes/No
No
Replace the switch.
No
Correct mechanical
operation.
No
Replace the switch.
No
Correct the
mechanism.
Yes
Replace the finisher
controller PCB.
Action
7-41