Step
Slide Terminal Blocks and spacer to the left of the Partition
4
location to the left to allow installation of the PV/AC Partition.
Install PV/AC Partition in the location specified in the site
5
engineering instructions.
Snap the Partition onto the DIN rail.
Slide the loosened Terminal Blocks and spacer block to the right
snugly against the Partition.
6
The Partition lower edge will be under the Terminal Block on its
left.
Tighten screws securing all DIN spacer blocks s to the left of the
7
Partition.
Apply labels to the Input Panel chassis.
Place "PV Wiring" label on the left (PV) side of partition.
8
Place the "AC Wiring" label on the right (AC) side of
partition.
9
Replace the Input Panel cover and secure fasteners.
Apply 2 labels to Input Panel cover in any available space.
Warning label
10
Max Power-Point label
850050111
Issue 03 August 2017
Action

Figure 29 Partition Insert

Figure 30 Label Input Panel

Figure 31 Label Input Panel Cover