Chapter 1 System Configuration
1
50
• DeviceNet
Assigned to inter-PC and remote I/O communications as a lower field transmission
device of model 2000.
Performs inter-controller and remote I/O communication as a lower field transmission
device.
Type
Module type
Transmission cable
Transmission method
Transmission speed
Max transmission distance
No. of stations
• FL-net
A LAN (local area network) for FA suitable for fast data link between controllers. It can
connect a controller from other vendor allowing a multi-vendor system. Data link with
the T-series controller is also possible.
There are two types of modules for model 2000:
•
Remote I/O station module
•
I/O module
The remote I/O station module can be mounted only on slot S0 of BU668/666/664.
Up to four I/O modules can be mounted on any I/O module slots.
•
Remote I/O station module
Type
Module type
Transmission Protocol
version
Transmission medium
Topology
Transmission speed
Max transmission distance
No. of stations
Transmission capacity
Response speed
Communication Function
Table 1-40 DN611A specification
G2 I/O module
DeviceNet cable
Party line/branch line
125kbps
500m
Max. 64 stations(including own station)
Table 1-41 FL654 specifications
remote I/O station module
FA control network FL-net(OPCN-2)
protocol version 2.00
500m/system
100m/segment
Max. 256 stations/bus
8192words + 8192 bit
Min. 50ms /32 stations,2048word
(1) Cyclic transmission/(2) Message transmission
model 2000 Sequence Controller S2 User's Manual -Basic Hardware-
DN611A
250kbps
500kbps
250m
100m
FL654
10BASE-T
Bus
10Mbps