Starting Engine

Follow the steps below to start the engine without depressing
accelerator pedal (3).
1. Check that both forward/reverse lever (8) and forward/
reverse switch (9) are in the neutral (N) position and
neutral lever lock (10) is in the LOCK position.
2. Check that parking brake switch (1) is ON.
3. Turn the key switch (2) ON.
4. Check indicator bulbs
When key switch (2) is turned ON, all indicators and the
warning lights come and stay ON for 2 seconds. Then,
they go OFF afterward. Any indicator and/or warning
light that fails to light at this time is a burned bulb.
However, discharge warning indicator (5) will continue
to stay ON, and it will go OFF only after the engine is
started.
Preheating will automatically start with the key switch
ON. Preheat indicator (6) will automatically come ON.
5. Check that parking brake indicator (7) is ON. When
preheat indicator (6) goes OFF (the engine has
preheated), sound the horn to clear any personnel away
from the area surrounding the machine.
f
NOTE: The monitor display turns off momentarily when
starting the engine, but this is normal.