Stop the Machine

1. Avoid sudden deceleration. Smoothly reduce the drive
speed.
Release accelerator pedal (1) and step on brake pedal (2)
to stop the machine on level surface.
2. Return forward/reverse lever (3) and forward/reverse
switch (7) to neutral (N).
Place neutral lever lock (4) to the LOCK position.
3. Press the ON side of parking brake switch (5).
4. Level the bucket with the surface of the ground and
lower the bucket to the ground by operating control
lever (6).
5. Press LOCK ( ) side of control lever lock switch (8).
IMPORTANT: This machine is equipped with a
turbocharged engine. Therefore if the engine is
stopped without performing cooling down operation,
the lubricant on the turbocharger bearing surfaces
may desiccate due to the intense heat present,
possibly causing damage to the turbocharger.
6. Run the engine at slow idle speed for 5 minutes to cool
the engine.
DRIVING MACHINE
6
7
4-13
5
3
4
2
1
8
Stop and Parking Position
MNDB-01-002
MNDB-01-005
MNSC-04-002