2 Prerequisites and Dependencies
Figure 2-7
Apart from the infeed, the response for F51057 (CommonSignals_External Off1
interlock missing) must be set in p2100 and p2101 of every SINAMICS element
(e.g. CU, input/output components, drives etc.) to "[0] NONE", instead, logic inside
of the DCC will have an OFF1 response to this fault.
Extended Crane Drive-Based Technology AC
Extended Crane Drive-Based Technology SINAMICS S120
DCC Add-On Description 109767457,
Example of changing fault response responses for faults using parameters
p2100 and p2101
V1.2,