Siemens SINAMICS S120 Manual page 43

Drive-based technology dcc addon description
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

3 DCC Blocks
SINAMICS
parameter
number
p22170
H1_rTorqueBuildingSpeed
SetpointRamptime (%)
r22190
H1_boOut_SP_EnableBrake
StoreValue (p22070)
r22191
H1_rOut_SP_TorqueValue
Retain (p22071)
r22192
H1_boOut_SP_Command
OpenBrake (p22072)
r22193
H1_boOut_SP_Command
CloseBrake (p22073)
r22194
H1_rOut_ActualTorque (%)
r22195
H1_rOut_SpeedControllerI-
ComponentAtPreviousBraking (%)
r22196
H1_rOut_ActualTorqueAtPrevious
Braking (%)
r22197
H1_rOut_TorqueToBeProven (%)
r22198
H1_boOut_TorqueProvingOk (%)
r22199
H1_boOut_CloseBrake (p1224.2)
Extended Crane Drive-Based Technology AC
Extended Crane Drive-Based Technology SINAMICS S120
DCC Add-On Description 109767457,
Name
Connection
V1.2,
09/2019
Default
type
assignment
IN
5000
OUT
0
OUT
0
OUT
0
OUT
0
OUT
0
OUT
0
OUT
0
OUT
0
OUT
0
OUT
0
Data
Meaning
type
REAL
Time period over
which p22169
(H1_Torque
BuildingSpeed
SetpointLimit (%)) is
built for hoist 1
BOOL
Output from p22070
(StartPulse_boEnable
BrakeStoreValue)
from hoist 1
REAL
Output from p22071
(StartPulse_rTorque
ValueRetain [%])
from hoist 1
BOOL
Output from p22072
(StartPulse_bo
CommandOpen
Brake) from hoist 1
Output from p22073
BOOL
(StartPulse_bo
CommandClose
Brake) from hoist 1
REAL
Output of r80[1] (CO:
Torque actual value,
Smoothed with
p0045) from hoist 1
REAL
Output of r1482 (CO:
Speed controller I
torque output) from
hoist 1
Output of r80[1] (CO:
REAL
Torque actual value,
Smoothed with
p0045) at previous
braking from hoist 1
Torque to be proven
REAL
for hoist 1, either the
value set in p22164
(H1_rMinimumTorque
(%)) or r22196
(H1_rOut_Actual
TorqueAtPrevious
Braking (%)), which
ever value is larger.
BOOL
Verification that all
conditions to satisfy
torque proving have
been met
BOOL
Output of r1224[2]
(BI: Close motor
holding brake at
standstill) from hoist 1
43