Mitsubishi Electric MELSEC-A0J2H Series Handbook page 214

Table of Contents

Advertisement

Specifications
A0J2-E28AS output specifications
Number of output points
Insulation method
Rated switching voltage
Maximum switching
voltage
Maximum switching
current
Minimum switching
24VAC100mA, 100V/240VAC10mA
voltage/current
Maximum inrush current
Leakage current at off
Maximum voltage drop
at on
Temperature derating
OFFON
Response
time
ONOFF
Fuse rating
Fuse blown indication
(LED turns on by fuse blown, and a
signal is output to the CPU module.)
CR
Surge
absorber
suppressor
Varistor
Common terminal
arrangement
Operation indication
(Turning ON the input turns LED ON)
Specifications
5VDC internal current
consumption
External
Voltage
supply
power
(Module
power
Current
supply)
External connection
36-point terminal block connector
method
Applicable wire size
(Applicable tightening torque 69N•cm)
Applicable solderless
terminal
Weight
External dimensions
App
- 19
12 points
Photocoupler
100 to 240VAC, 40-70Hz
264VAC
0.6A/point, 2.4A/common
20A10ms or less
8A100ms or less
1.5mA (120VAC60Hz)
3mA (240VAC60Hz)
1.5V or less (0.1A-0.6A)
1.8V or less (0.1A or less)
2.0V or less (10-50mA)
None
1ms or less
0.5 cycle + 1ms or less
Fast blow fuse 3.2A
(1/common) HP-32
Available
0.022µF+47
None
8 points/common
(Common terminal: TB26)
4 points/common
(Common terminal: TB33)
Available
A0J2-E28AS
260mA (TYP. All points are ON.)
None
None
(M3 × 6 screws)
2
0.75 to 2mm
1.25-3, 1.25-YS3A, 2-S3,
2-YS3A, V1.25-3, V1.25-YS3A,
V2-S3, V2-YS3A
0.68kg
250(H) × 132(W) × 41(D)mm
SC-A0JQIF28AS output
specifications
12 points
Photocoupler
100 to 240VAC, 47-63Hz
264VAC
0.6A/point, 2.4A/common
24VAC100mA, 100V/240VAC10mA
20A10ms or less
8A100ms or less
1.5mA (120VAC60Hz)
3mA (240VAC60Hz)
1.5V or less (0.1A-0.6A)
1.8V or less (0.1A or less)
2.0V or less (10-50mA)
*3
Refer to temperature derating chart
1ms or less
0.5 cycle + 1ms or less
None
None
0.015µF+22
Varistor (400 to 540V)
8 points/common
(Common terminal: TB26)
4 points/common
(Common terminal: TB33)
None
SC-A0JQIF28AS
24VDC ±10%
Ripple voltage 4Vp-p or less
290mA
36-point terminal block connector
(M3 × 6 screws)
2
0.75 to 2mm
(Applicable tightening torque 69N•cm)
1.25-3, 1.25-YS3A, 2-S3,
2-YS3A, V1.25-3, V1.25-YS3A,
V2-S3, V2-YS3A
0.43kg
*6
182(H) × 132(W) × 41(D)mm
Compatibility
Precautions for replacement
Use it within the range shown in the
temperature derating chart.
In combination with Q series input
module:
2ms or less (6ms TYP.)
In combination with Q series input
module:
0.5 cycle + 2ms or less.
Install one fuse per common externally.
×
The fuse and fuse holder are included.
×
Operation indication can be checked
with Q series input module.
Compatibility
Precautions for replacement
To deliver a power for programmable
controller operation, connecting a
×
module power supply to the interface
module, TB35 or TB36 is required.
If the voltage exceeds existing power
×
capacity, add 24VDC power supply
separately.
Also consider the weight of fixed stand
of programmable controller.
Check the dimensions since they
×
depend on the installation type
(building-up/horizontal/separate type).
*4
*4
*5