3
I/O MODULES REPLACEMENT
(14)Specifications comparison between A0J2E-E28DR and QX80+QY10
Specifications
Number of input points
Insulation method
Rated input voltage
Rated input current
Operating voltage range
Maximum number of
simultaneous input
points
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Input format
OFFON
Response
time
ONOFF
Response
OFFON
time high-
speed
mode (Only
upper 8
ONOFF
points)
Common terminal
arrangement
Operation indication
A0J2E-E28DR input
specifications
16 points
Photocoupler
12VDC/24VDC
3mA/7mA
10.2 to 26.4VDC
(Ripple ratio within 5%)
100% simultaneously ON
9.5VDC or more/2.6mA or more
19VDC or more/3mA or more
6VDC or less/1.0mA or less
11VDC or less/1.7mA or less
Approx. 3.4k
Source input
(Input current flows in.)
1ms/5ms/10ms/20ms/70ms or
5.5ms or less (TYP.)
(Set it with CPU parameter.)
1ms/5ms/10ms/20ms/70ms or
6.0ms or less (TYP.)
(Set it with CPU parameter.)
1ms/5ms/10ms/20ms/70ms or
0.5ms or less
(Set it with CPU parameter.)
1ms/5ms/10ms/20ms/70ms or
1.0ms or less
(Set it with CPU parameter.)
16 points/common
(Common terminal: TB17)
Available (Turning ON the input
turns LED ON)
: Compatible,
QX80
Compatibility
16 points
Photocoupler
24VDC
Approx. 4mA
20.4 to 28.8VDC
(Ripple ratio within 5%)
100% simultaneously ON
Approx. 5.6k
Negative common
less
Initial setting is 10ms.
less
Initial setting is 10ms.
less
Initial setting is 10ms.
less
Initial setting is 10ms.
16 points/common
(Common terminal: TB18)
ON indication (LED)
: Partially changed, × : Incompatible
Precautions for replacement
*1
12VDC cannot be used.
*2
Rated input current is smaller.
*1
12VDC cannot be used.
*1
12VDC cannot be used.
*1
12VDC cannot be used.
*2
Input resistance is greater.
The name is different, but the
specificaton is equal.
Set the input response time of the
parameter to 5ms before use.
Set the input response time of the
parameter to 1ms before use.