Product description
3.3 Basic versions
Terminal
ST
RF1
RF2
P1
P2
MAG
EA1
EA2
U
3TK2810-1.A4.-0AA0 only: U1
GND
3TK2810-1.A4.-0AA0 only: U2
E1
E2
Interfaces of the 3TK2810-1 speed monitor
Interface
RJ45
Operator control elements of the 3TK2810-1 speed monitor
Element
Keys
Display elements of the 3TK2810-1 speed monitor
Element
DEVICE
13/14
23/24
SF
Display
28
Function
Start of the drive
Feedback circuit 1 input
Feedback circuit 2 input
Input for position switch channel 1
Input for position switch channel 2
Input for solenoid monitoring (contact closed/open when magnet
attracted/repelled)
Setup speed/automatic speed channel 1 switchover
Setup speed/automatic speed channel 2 switchover
Connection of proximity switch channel 1+2
Connection of proximity switch channel 1+2
Proximity switch 1 signal input
Proximity switch 2 signal input
Meaning
Interface for connecting the encoder and for the copy function
Meaning
Navigation in the operator control menu / error acknowledgement
Display
Meaning
Green
Device OK
Flashing green Parameterizing mode
Flashing red
Parameterization error
Red
Device defective
Green
Output contact 13/14 closed
Flashing green Switch-off monitoring feedback circuit 2 failed
Green
Output contact 23/24 closed
Flashing green Switch-off monitoring feedback circuit 1 failed
Off
No error
Red
(External) error
Diagnostics
Error messages
Status indicator, possibly parameterization