8.4.4

Fault in the feedback circuit

8.4.4.1

Contacts of the feedback circuit are not closed on starting

Connection of output contact 13/14 or 23/24 is only possible if the relevant feedback contact is
closed.
A fault message is not displayed.
8.4.4.2

Contacts of the feedback circuit do not close after stopping

If the contacts of the feedback circuit do not close after the device is stopped, the contactors are
still energized or defective. A message is displayed.
A restart or reset is necessary following correction of the fault.
8.4.5

Cross-circuit/short-circuit

If a cross-circuit or short-circuit is detected, the device switches to the safe state. An error
message is generated and the diagnostics provides information on the location of the fault.
A restart or reset is necessary following correction of the fault.
8.4.6

Fault in the connection to the adapter

If an adapter module has been parameterized and the connection to the adapter is interrupted,
or the adapter signals a fault, the device switches to the safe state. An error message is
generated and the diagnostics provides information on the location of the fault.
A restart or reset is necessary following correction of the fault.
8.4.7

Violation of upper/lower parameterized speed limits

8.4.7.1

Automatic speed exceeded

If the parameterized maximum automatic speed is exceeded, the device switches immediately
to the safe state. Contacts 23/24 are opened and when the lower parameterized standstill speed
limit is violated, contacts 13/14 are closed. The corresponding signaling outputs are switched.
8.4.7.2

Automatic speed undershot

If the parameterized minimum automatic speed is undershot, the device switches immediately
to the safe state. Contacts 23/24 are opened and when the lower parameterized standstill speed
limit is violated, contacts 13/14 are closed. The corresponding signaling outputs are switched.