Figure 5-2 Stripping a power cable (OT terminal)
l When you strip a power cable, do not damage the conductor of the cable.
l If the bare crimping terminal is not provided by Huawei, the value of L1 is 1 mm (0.04 in.)
Table 5-1 Mapping between the cross-sectional area of the conductor and the value of L1
Cross-
Sectional
Area of
Conductor
(mm
1 (0.002)
1.5 (0.002)
2.5 (0.004)
4 (0.006)
6 (0.009)
Step 2 Put the heat-shrinkable (A) tubing onto the bare crimping terminal, as shown in
Issue 05 (2016-07-22)
NOTICE
to 2 mm (0.08 in.) greater than the value of L.
Value of L1
(mm(in.))
2
2
(in.
))
7 (0.28)
7 (0.28)
7 (0.28)
8 (0.31)
9 (0.35)
NOTE
If you are proficient in assembling OT terminals and power cables, you can obtain the value of L1 by
comparing the part to be crimped with the power cable.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Cross-Sectional
Area of Conductor
2
2
(mm
(in.
))
10 (0.015)
16 (0.025)
25 (0.039)
35 (0.054)
50 (0.077)
5 Appendix
Value of L1
(mm(in.))
11 (0.43)
13 (0.51)
14 (0.55)
16 (0.63)
16 (0.63)
Figure
5-3.
28