(12) When the Regeneration Option Is Used
1. Remove the jumper between terminals P and D on the CNP2 connector of the replacing servo
amplifier.
2. Connect the cables on terminals P and C on the terminal block (TE2) of Renewal Kit to the
replacing servo amplifier.
3. Connect the regeneration option to terminals P and C on the terminal block (TE2) of Renewal
Kit.
* For the details of how to connect the cables of the regeneration option, see the technical
materials on the MR-J4 servo amplifier issued by Mitsubishi Electric Corporation.
(13) When the Power Regeneration Converter Is Used
1. Remove the jumper between terminals P and D on the CNP2 connector of the replacing servo
amplifier.
2. Connect the cables on terminals P and N on the terminal block (TE2) of Renewal Kit to the
replacing servo amplifier.
3. Connect the power regeneration converter to terminals P and N on the terminal block (TE2) of
Renewal Kit.
*
For the details of how to connect the cables of the power regeneration converter, see the
technical materials on the MR-J4 servo amplifier issued by Mitsubishi Electric Corporation.
Connect the terminal cables of Renewal Kit.
・In the case of the regeneration option
・In the case of the power regeneration converter ...Terminals P and N
*Terminal N to connector CNP1 of servo amplifier MR-J4
Remove the jumper from
terminals P and D.
Connector CNP2
...Terminals P and C
Connect the currently used cable to the terminal block (TE2)
of Renewal Kit.
・In the case of the regeneration option
...Terminals P and C
・In the case of the power regeneration converter
...Terminals P and N
3-23