●Before resetting an alarm, make sure that the run signal of the servo amplifier is off in order to prevent a
sudden restart. Otherwise, it may cause an accident.
●Use a noise filter, etc. to minimize the influence of electromagnetic interference. Electromagnetic
interference may be given to the electronic equipment used near the servo amplifier.
●Burning or breaking a servo amplifier may cause a toxic gas. Do not burn or break it.
●Use the servo amplifier with the specified servo motor.
●The electromagnetic brake on the servo motor is designed to hold the motor shaft and should not be used
for ordinary braking.
●For such reasons as service life and mechanical structure (e.g. where a ball screw and the servo motor
are coupled via a timing belt), the electromagnetic brake may not hold the motor shaft. To ensure safety,
install a stopper on the machine side.
(5) Corrective actions
●When it is assumed that a hazardous condition may occur due to a power failure or product malfunction,
use a servo motor with an electromagnetic brake or external brake to prevent the condition.
●Configure an electromagnetic brake circuit so that it is activated also by an external EMG stop switch.
Contacts must be opened with the ALM
(malfunction) off or the MBR
(electromagnetic brake interlock) off.
●When any alarm has occurred, eliminate its cause, ensure safety, and deactivate the alarm before
restarting operation.
●Provide an adequate protection to prevent unexpected restart after an instantaneous power failure.
(6) Maintenance, inspection and parts replacement
●With age, the electrolytic capacitor of the servo amplifier will deteriorate. To prevent a secondary accident
due to a malfunction, it is recommend that the electrolytic capacitor be replaced every 10 years when it is
used in general environment. Please contact your local sales office.
(7) General instruction
●To illustrate details, the equipment in the diagrams of this Replacement Manual may have been drawn
without covers and safety guards. When the equipment is operated, the covers and safety guards must
be installed as specified. Operation must be performed in accordance with Instruction Manual.
CAUTION
CAUTION
Contacts must be opened with the EMG
stop switch.
Servo motor
RA
Electromagnetic
B
brake
U
CAUTION
A-5
A - 5
DC24V

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j2s

Table of Contents