Recommended 24Vdc Power Supply Specifications For Interface - Mitsubishi Electric MELSERVO-J2S Series Manual

Hide thumbs Also See for MELSERVO-J2S Series:
Table of Contents

Advertisement

(4) SC-J2SJ4KT5K (Note 1)
L11
L21
L1
L2
L3
N-
P3
P4
P+
C
D
U
Renewal kit
V
Junction terminal block
W
Note 1. There is no conversion terminal block for the MR-J2S-500_ and MR-J2S-700_ amplifier because the recommended wiring and
screw sizes are the same as for the MR-J4 amplifier. Connect the existing wiring, except for the junction terminal block of the
renewal kit mentioned above, directly to the J4 amplifier.
(6) SC-J2SJ4KT15K (Note 2)
TE1- 1
L1 L2 L3
U
V
Terminal screw: M6
Tightening torque: 3.0[Nm]
TE1- 2
P
(P
)
(P
)
P(P+)
C
1
3
4
Terminal screw: M6
Tightening torque: 3.0[Nm]
TE2
L
L
11
21
Terminal screw: M4
Tightening torque: 1.2[Nm]
Note 2. The renewal kits for the MR-J2S-11k_, MR-J2S-15k_, and MR-J2S-22K_ amplifiers have a different terminal position than the
MR-J2S amplifier. See 3.3.7 for the wiring method.
2.6.3 Recommended 24VDC Power Supply Specifications for Interface
These are the recommended specifications for the 24 V DC power supply for the interface necessary for renewal.
Select according to the following specifications.
Product name
For interface
24 V DC power
N- P3 P4
L1 L2 L3
L11
L21
W
N(N-)
PE
Terminal screw: M6
Tightening torque: 3.0[Nm]
Specifications
24 V DC, ±10%.
Current capacity: 80 mA or more.
(5) SC-J2SJ4KT7K (Note 1)
C U
V W
P+
Renewal kit
Junction terminal block
(7) SC-J2SJ4KT22K (Note 2)
TE1- 1
L1 L2 L3
U
V
Terminal screw: M8
Tightening torque: 6.0[Nm]
TE1- 2
P
(P
)
(P
)
P(P+)
C
1
3
4
Terminal screw: M8
Tightening torque: 6.0[Nm]
TE2
PE
L
L
11
21
Terminal screw: M4
Terminal screw: M8
Tightening torque: 1.2[Nm]
Tightening torque: 6.0[Nm]
2-44
2 - 44
L11 L21
N-
W
N(N-)