Triggercontrol - Toshiba BU Series Instruction Manual

Cmos camera
Hide thumbs Also See for BU Series:
Table of Contents

Advertisement

TriggerControl

This section describes trigger control of TriggerControl category for the BU series.
This camera series provides two kinds of exposure synchronization.
1. Normal Shutter mode
2. Random Trigger Shutter mode
In Random Trigger Shutter mode, two kinds of trigger input are available.
1. Trigger signal via the I/O connector (HardwareTrigger)
2. Trigger command via the USB interface (SoftwareTrigger)
The following table shows the combination of operation mode of this camera series.
Trigger Mode
Normal Shutter mode
Random Trigger Shutter mode
Copyright © 2016 – 2019 Toshiba Teli Corporation, All rights reserved.
: Free run operation (internal synchronization)
: Synchronized with external trigger input
Table. Operation Mode
Synchronization
Free run
-Edge mode:TriggerSequence0
HardwareTrigger
-Bulk mode:TriggerSequence6
-Edge mode:TriggerSequence0
SoftwareTrigger
-Bulk mode:TriggerSequence6
* The camera operation not mentioned above is not guaranteed.
48 / 80
Exposure Control
"ExposureTime" register control
"ExposureTime" register control