- Set the UserOutput signal
Set the following value to "UserOutputValueAll" register. Setting value is Integer type.
Each bit corresponds to each Line (bit0=Line0, bit1=Line1, bit2=Line2).
Line1 and Line2 are available. Line0 is dedicated input.
- Select the polarity of each signal
Set the following value to "LineInverterAll" register. The setting value is Integer type.
Each bit corresponds to each Line. All Lines are settable.Inverter is also inserted to UserOutputValue.
(GPIO_Input)
(GPIO_Input/Output)
(GPIO_Output)
● Note
The units of ExposureActive period is 15.7 usec. Then, the ExposureActive period may not correspond to
the setting of ExposureTime.
About the details of Timer0Active signal, refer to "TimerControl" of "Functions".
Copyright © 2016 – 2019 Toshiba Teli Corporation, All rights reserved.
UserOutputValueAll
0 (*)
1
LineInverterAll
0 (*)
1
Line0
Line2
Line1
LineModeAll
GPIO internal circuit diagram
Function
Low level output
High level output
* initial factory setting
Function
non inverted
inverted
* initial factory setting
TriggerSource
Internal Trigger
Timer0Active
UserOutput
ExposureActive
FrameTransfer
FrameActive
FrameTriggerWait
UserOutput
Internal Trigger
LineInverterAll
LineSource
55 / 80
TimerControl
UserOutputValueAll[2]
UserOutputValueAll[1]
D4256843D
http://www.toshiba-teli.co.jp/en/index.htm
xB