● Note
In Bulk function, you may want to set "Continuous" to "AcquisitionMode" register.
You can set "MultiFrame", but acquisition frame number is limited by "AcquisitionFrameCount.
AcquisitionMode = MultiFrame
AcquisitionFrameCount = 2
TriggerMode = On
TriggerSequence = 6
TriggerAdditionalParameter = 3
Start
Acquisition
Command
The trigger can be input in arbitrary timing.
Trigger
Exposure
Frame 1
*Exposure time is determined by ExposureTime setting.
USB Streaming
Copyright © 2016 – 2019 Toshiba Teli Corporation, All rights reserved.
Frame 2
Frame 3
TriggerAdditionalParameter
Frame 1
Frame 2
AcquisitionFrameCount
Stop
This exposure is
discarded.
Stream
stops