● Registers
Name
AntiGlitch
AntiChattering
● Setting
- Set the integration time for AntiGlitch.
Set the integration time to "AntiGlitch Value" register.
Trigger signal is delayed by AntiGlitch setting.
The setting is applied to the GPIO Input of Line0 and Line2.
- Set the insensible time for AntiChattering.
Set the insensible time to "AntiChattering Value" register.
The setting is applied to the GPIO Input of Line0 and Line2.
Copyright © 2016 – 2019 Toshiba Teli Corporation, All rights reserved.
Visibility
Access
Expert
R/W
Integration time of digital input signal. (Absolute value)
Expert
R/W
Insensible time of digital input signal. (Absolute value)
AntiGlitch
Minimum (*)
Maximum
AntiChattering
Minimum (*)
Maximum
57 / 80
Description
Integration time
[sec]
0.000 000 090
0.002
* initial factory setting
Insensitive time
[sec]
0.000 001 992
0.001 999 992
* initial factory setting
http://www.toshiba-teli.co.jp/en/index.htm