Panasonic WJ-SX 150A Operating Instructions Manual page 72

Panasonic matrix switcher wj-sx150a operating instructions
Table of Contents

Advertisement

740 CAMERA/DATA1-4 PORT
SWITCHER=MASTER(5 of 5)
PORT
MODE
CAMERA
TERMINAL-K1
DATA1
TERMINAL-K2
DATA2
TERMINAL-K3
DATA3
MASTER-SLAVE
DATA4
PS-DATA
HDR
HDR
SERIAL
PC
Master unit setting for Master-Slave connection
740 CAMERA/DATA1-4 PORT
SWITCHER=SLAVE1(1 of 5)
PORT
MODE
CAMERA
CAMERA
DATA1
CAMERA
DATA2
CAMERA
DATA3
CAMERA
DATA4
MASTER-SLAVE
HDR
HDR
SERIAL
--
Slave unit setting for Master-Slave connection
SWITCHER: Select a unit (SLAVE1 to 4 and MASTER*) to
configure the parameters.
* In normal connection, only MASTER is displayed.
The factory default setting is same as the illustration.
PORT: This stands for the type of a port.
CAMERA: RS-485 Camera port
DATA 1/2/3/4: DATA 1/2/3/4 ports
HDR: DATA HDR port
SERIAL: SERIAL port
MODE: This stands for the operation mode of a port.
CAMERA: Select this if a camera is connected.
TERMINAL-K1/K2/K3/K4: Select this if a terminal-mode
system controller is connected.
PS·DATA: Select this if a PS·DATA system controller is
connected.
MASTER-SLAVE: The port used for the master-slave
connection is fixed to this parameter.
HDR: The HDR port is fixed to this parameter.
PC: WJ-SX150A Administrator Console configuration
and firmware update becomes available with a PC
connection.
VCR: Select this if a time-lapse VCR (Panasonic model)
is connected.
– – –: This port is unusable.
The following are MODE parameters assigned to
each port.
75
SPEED
9600bps
9600bps
9600bps
38400bps
9600bps
9600bps
38400bps
SPEED
19200bps
19200bps
19200bps
19200bps
38400bps
9600bps
38400bps
Master
Port
Normal connection
CAMERA
CAMERA
TERMINAL-K1/K2/
DATA 1
K3/K4
CAMERA
TERMINAL-K1/K2/
DATA 2
K3/K4
CAMERA
TERMINAL-K1/K2/
DATA 3
K3/K4
CAMERA
TERMINAL-K1/K2/
DATA 4
K3/K4
PS
DATA
·
HDR
HDR
PC
SERIAL
VCR
The factory default setting is same as the illustration.
SPEED: This stands for the communication speed of a port.
38400 bps*: Select this to set the speed to 38400 bps.
19200 bps: Select this to set the speed to 19200 bps.
9600 bps: Select this to set the speed to 9600 bps.
4800 bps: Select this to set the speed to 4800 bps.
* This parameter is available only for SERIAL.
The factory default setting is same as the illustration.
Notes:
• If the DATA 4 is set to PS·DATA, SPEED of PS·DATA will
be changed in conjunction with that of HDR.
• When you change MODE, the default communication
speed is automatically set. The SERIAL port is set to the
default speed when CONTROL is changed in 600
RECORDER. (Refer to p. 71.)
The default communication speeds are shown in the dia-
gram.
MODE
CAMERA
TERMINAL
PS·DATA
HDR
PC
VCR (VTR)
Slave 1
to 4
Master-slave connection
TERMINAL-K1/K2/
K3/K4
CAMERA
CAMERA
TERMINAL-K1/K2/
K3/K4
CAMERA
CAMERA
TERMINAL-K1/K2/
K3/K4
CAMERA
CAMERA
MASTER-SLAVE
CAMERA
TERMINAL-K1/K2/
MASTER-
K3/K4
SLAVE
PS
DATA
·
HDR
HDR
PC
– – –
VCR
VCR
Factory default setting
19200 bps
9600 bps
9600 bps
9600 bps
38400 bps
9600 bps

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wj-sx155Wj-sx150a

Table of Contents