Modify Gate Time - Yamaha RS7000 Owner's Manual

Music production studio
Hide thumbs Also See for RS7000:
Table of Contents

Advertisement

4
Rate
[Settings] 000% ~ 200%, ***
Specifies the percentage by which the target notes will be
shifted from their original velocities.
Settings below 100% reduce the velocities, and settings
above 100% increase the velocities proportionately. When
the Set All parameter is not "OFF" this parameter appears as
"***" and cannot be changed.
Original velocity
(Vel)
96
Rate = 50%
(Vel)
48
(Vel)
Rate = 150%
127
5
Offset
[Settings] -127 ~ +127, ***
Adds a fixed value to the Rate-adjusted velocity values.
A setting of 0 produces no change. Settings below 0 reduce
the velocities, and settings above 0 increase the velocities.
When the Set All parameter is not "OFF" this parameter
appears as "***" and cannot be changed.
Original velocity
(Vel)
96
Rate = -20
(Vel)
76
(Vel)
Rate = +20
116

03 Modify Gate Time

This job alters the gate times of the specified range of notes.
Gate time changes are calculated as follows:
Adjusted gate time =
(original gate time × Rate) + Offset
If the result is 0 or less, the value is set to 1.
1
2
4
3
[Knob 2]
64
48
32
32
24
16
96
72
48
64
48
32
44
28
12
84
68
52
5
[Knob 3]
[F4]
14. Pattern & Phrase Editing — The Pattern Jobs
1
Phrase
[Settings] 001 ~ 256
Range
2
[Settings] Measure:Beat:Clock
001:1:000 ~ 257:1:000
Sets the range of measures/beats/clocks over which the job is
applied.
Set All
3
[Settings] Off (0), 0001 ~ 9999
Sets the gate times of all target notes to the same fixed value.
When set to "OFF" the Set All parameter has no effect.
When set to a value other than "OFF" the Rate and Offset
parameters are unavailable and appear as "***" on the dis-
play.
Rate
4
[Settings] 000% ~ 200%, ***
Specifies the percentage by which the gate time of the target
notes will be changed.
Settings below 100% shorten the notes, and settings above
100% lengthen the notes proportionately. When the Set All
parameter is not "OFF" this parameter appears as "***" and
cannot be changed.
Original gate time
(Gate)
Gate time rate = 50%
(Gate)
Gate time rate = 150%
(Gate)
Offset
5
[Settings] -9999 ~ +9999, ****
Adds a fixed value to the Rate-adjusted gate time values.
A setting of 0 produces no change. Settings below 0 shorten
the gate time, and settings above 0 lengthen the gate time.
When the Set All parameter is not "OFF" this parameter
appears as "****" and cannot be changed.
Original gate time
(Gate)
32
Offset = -20
(Gate)
12
Offset = +20
(Gate)
52
32
32
32
48
16
16
16
24
48
48
48
72
32
32
48
12
12
28
52
52
68
RS7000 137
2

Advertisement

Table of Contents
loading

Table of Contents