3.4.2 (For TPR-1600H)
Motor Part Name
Main Motor
Elevating Motor
Hydraulic Motor
Coolant Pump Motor
Total Rated Power Capacity:
Maximum Total Initiate Power Capacity:
Transformer Rated Output Power Capacity for Control Circuits
Item
Power Supply
Ambient Temperature
S=KVA
P=KW
Pf ×n = 0.75 (Correction Factors)
P=
P=
Power Equipment Capacity=
Rated Power Capacity
5.625kw
1.5kw
0.75kw
0.1kw
(5.625kw+1.5kw+0.75kw+0.1kw)=7.975kw................(1)
(15.75kw+4.2kw+2.1kw+0.28kw)=22.33kw................(2)
Model
100VA
Input
Output
0°C To 55°C
S=
7.975Kw
=10.633KVA....................... (1)
0.75
22.33Kw
=29.773KVA....................... (2)
0.75
10.633KVA+29.773KVA
AC400V±10% 1∅
AC240V±10% 1∅
KW
Pf×n(0.75)
=20.203KVA
2
3-6
Maximum Initiate Power
15.75kw
4.2kw
2.1kw
0.28kw