Sharp RD-1230 Operation Manual page 26

Radial drills
Table of Contents

Advertisement

3.4.3 (For TPR-2000H)
Motor Part Name
Main Motor
Elevating Motor
Hydraulic Motor
Coolant Pump Motor
Total Rated Power Capacity:
Maximum Total Initiate Power Capacity:
Transformer Rated Output Power Capacity for Control Circuits
Item
Power Supply
Ambient Temperature
S=KVA
P=KW
Pf ×n = 0.75 (Correction Factors)
P=
P=
Power Equipment Capacity=
Rated Power Capacity
5.625kw
2.25kw
0.75kw
0.1kw
(5.625kw+2.25kw+0.75kw+0.1kw)=8.725kw................(1)
(15.75kw+6.3kw+2.1kw+0.28kw)=24.43kw................(2)
Model
100VA
Input
Output
0°C To 55°C
S=
8.725Kw
=11.633KVA....................... (1)
0.75
24.43Kw
=32.573KVA........................ (2)
0.75
11.633KVA+32.573KVA
AC400V±10% 1∅
AC240V±10% 1∅
KW
Pf×n(0.75)
=22.193KVA
2
3-7
Maximum Initiate Power
15.75kw
6.3kw
2.1kw