6.3 Adjust tighten the clamping device
After the machine has been used a period of time, the tighten the clamping device. It is the
time to adjust its tightness clamping device of adjusting nut.
6.3.1(For TPR-1230, TPR-1230H)
Adjust tighten the clamping device lever as follows:
a. Switch the cross switch to ARM UP 。
b. Press the emergent stop button after the Arm elevates a little bit.
c. Release the clamping device and adjust the bolts and nuts.
d. Adjust the nut one notch clockwise.
e. Switch the cross switch to the middle.
f. Reset the emergent stop button.
6.3.2 (Application model: TPR-1600H, TPR-2000H)
The way to clamp the arm follows as:
a. Turn the cross switch to ARM UP 。
b. After the arm lifts a little bit, press down the emergency stop.
c. Release the fastening nut.
d. Rotate the adjustment nut half circle clockwise.
e. Clamp the fastening nut.
f. Turn the cross switch to the middle.
g. Reset the emergency stop.
Part
1.
clamping device of adjusting nut
position
1
Adjust the nut.
2
Fasten the nut.
6-3
Name
Name