Power Supply Unit; Cold Redundant Feature - NEC E120e-M User Manual

Table of Contents

Advertisement

Chapter 2 Preparations
1.14

Power Supply Unit

Your server can contain two power supply units. The server equipped with two hot-swap power supply units
provides a redundant power configuration that ensures continued operation of the system in the unlikely event
one of the power supply units fails.

1.14.1 Cold Redundant Feature

The server supports the feature to optimize power efficiency as described below:
Cold redundant feature can run the system with optimum power efficiency by raising operating efficiency of
primary power supply unit and lowering that of redundant power supply unit in redundant power
configuration.
If power efficiency of power units is not optimized due to system configuration, this feature is disabled
automatically.
Cold redundant feature can be used under the following conditions:
Two power supply units must be installed for redundant configuration.
Refer to Chapter 3 (2. System BIOS Setup), change parameters as shown below, save the settings and exit
from SETUP.
Server → Power Control Configuration → Cold Redundant Mode → Enabled
Run SETUP again, and check if the status of Cold Redundant Mode shows Enabled in Server menu.
90
Express5800/E120e-M User's Guide
1. Installing Internal Optional Devices

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800 seriesN8100-2103fN8100-2104f

Table of Contents